ESFR (Early Suppression Fast Response) Sprinkler
ESFR sprinklers has 3 difference compared to other sprinklers;
Speed – ESFR sprinkler are twice faster to detect and active compared to other type sprinklers.
Volume – While other sprinklers blow 25-60gpm water, ESFR sprinklers blow water up to 100gpm.
Drop size – ESFR sprinkler heads blow bigger water drops compared to other sprinklers.
ESFR – K:14 (200) Pendent
- Connection: ¾”npt
- Assembly: Pendent (Hanging) Type
- K-Factor: 14 (200)
- Approval: FM, UL, ULC, LPCB, VdS
- Temperature: 74°C, 96°C
- Surface: Brass
- Sin:VK500- ESFR(Early Suppression, Fast Response)
- – Sensitive to temperature provided by fusible link.
- – Warehouse type sprinkler is designed for the special applications such as high level storage systems. These type of sprinklers gives the more water with more less pressure.
- – If the users do correct pressure adjustments for ESFR Sprinklers, users don’t need any other sprinkler use for the between shelf.
Documents
ESFR – K:14 (200) Upright
- Connection: ¾”npt
- Assembly: Upright
- K-Factor: 14 (200)
- Approvals: FM
- Temperature: 74°C, 96°C
- Surface: Brass
- Sin: VK520- ESFR(Early Suppression, Fast Response)
- – Sensitive to temperature provided by fusible link.
- – Warehouse type sprinkler is designed for the special applications such as high level storage systems. These type of sprinklers gives the more water with more less pressure.
- – If the users do correct pressure adjustments for ESFR Sprinklers, users don’t need any other sprinkler use for the between shelf.
- – Provided with unique upright design it’s the only solution where it’s not possible to use pendent sprinklers.
Documents
ESFR – K:16.8 (242) Pendent
- Connection: ¾”npt
- Assembly: Pendent
- K-Factor: 16.8 (242)
- Approvals: FM, UL, ULC, LPCB, VdS
- Temperature: 74°C, 96°C
- Surface: Brass
- Sin: VK503- ESFR(Early Suppression, Fast Response)
- – Sensitive to temperature provided by fusible link.
- – Warehouse type sprinkler is designed for the special applications such as high level storage systems. These type of sprinklers gives the more water with more less pressure.
- – If the users do correct pressure adjustments for ESFR Sprinklers, users don’t need any other sprinkler use for the between shelf.
- – Requires lower pressure compared to ESFR K:14
Documents
ESFR – K:22.4 (320) Pendent
- Connection: 1”npt
- Assembly: Pendent
- K-Factor: 22.4 (320)
- Approvals: FM, UL, ULC, LPCB, VdS
- Temperature: 74°C, 96°C
- Surface: Brass
- Sin: VK506- ESFR(Early Suppression, Fast Response)
- – Sensitive to temperature provided by fusible link.
- – Warehouse type sprinkler is designed for the special applications such as high level storage systems. These type of sprinklers gives the more water with more less pressure.
- – If the users do correct pressure adjustments for ESFR Sprinklers, users don’t need any other sprinkler use for the between shelf.
- – Requires lower pressure compared to ESFR K:17
Documents
ESFR – K:25 (363) Pendent
- Connection: 1”npt
- Assembly: Pendent
- K-Factor: 25 (363)
- Onaylar: FM, UL, ULC, LPCB, VdS
- Temperature: 74°C, 96°C
- Surface: Brass
- Sin: VK510- ESFR(Early Suppression, Fast Response)
- – Sensitive to temperature provided by fusible link.
- – Warehouse type sprinkler is designed for the special applications such as high level storage systems. These type of sprinklers gives the more water with more less pressure.
- – If the users do correct pressure adjustments for ESFR Sprinklers, users don’t need any other sprinkler use for the between shelf.
- – Requires lower pressure compared to ESFR K:22.4
Documents
Inquiry Form
Please send us your inquiry using our contact form and we will contact you immediately.